|
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Total Units Connected: 2141 |
|
|
Harvest Irrigation Monitor Pricing
|
|
Mains Powered Non-Weather Proof Systems
Wall mount, mains powered, backup battery and splash proof powder coated steel enclosure |
 |
Basic Non-Wireless System
Ability to monitor up to two flow meters and depth sensor or pressure sensor |
$1500 |
 |
G1 Multi Input Monitor (Indoor)
Ability to monitor up to four flow meters and up to six depth or pressure sensors |
$2000 |
 |
Advanced G2 Non-Wireless System
Ability to monitor up to eight flow meters and up to eight depth or pressure sensors
SDI-12 input and dual relay ouptuts |
$2300 |
 |
Advanced G2 Wireless System
Ability to monitor up to eight flow meters and up to eight depth or pressure sensors
SDI-12 input, dual relay output plus both standard and long range wireless capabilities |
$2650 |
| |
|
Solar Powered Weather Proof Systems
Solar Powered with waterpoof stainless steel casing with 2" pipe mount bracket |
 |
Basic Non-Wireless System
Ability to monitor up to two flow meters and depth sensor or pressure sensor |
$1650 |
 |
Standard G1 Wireless System
Ability to monitor up to four flow meters and up to six depth or pressure sensors |
$2100 |
 |
Advanced G2 Non-Wireless System
Ability to monitor up to eight flow meters and up to eight depth or pressure sensors
SDI-12 input and dual relay ouptuts |
$2400 |
 |
Advanced G2 Wireless System
Ability to monitor up to eight flow meters and up to eight depth or pressure sensors
SDI-12 input, dual relay output plus both standard and long range wireless capabilities
|
$2750 |
Sensors:
 |
Long Range Multi Input Transmitter
Used for monitoring soil moisture, pump on/off, well/bore depth, flow meters and pipe pressure (G2 Systems only) |
 |
Rain Gauge Davis 0.2mm tip |
 |
Wind speed/direction Davis |
 |
Temperature/Humidity sensor
Used to calculate dew point and wet bulb |
 |
Soil Moisture probe Decagon 10HS
Sample size of just under 1 litre |
 |
Soil Moisture/Temperature probe Aquaflex SI.99
High end sensor with a sampling area of over 3 litres |
 |
Multi Level Soil Moisture probe Sentek EasyAg 30 or 50
Samples at either 3 or 5 levels 10cm apart, low impact installation |
 |
Leaf Wetness sensor Decagon LW1
Used to calculate Bacchus Botrytis risk |
 |
Soil Temperature sensor
Calibrated by Harvest to 0.01°C |
 |
Water Temperature sensor
Calibrated by Harvest to 0.01°C |
 |
Solar Radiation sensor Davis
Used to calculate Evapotranspiration |
 |
UV sensor Davis
Used to calculate UV index |
 |
Submerisable water depth pressure sensor PMC VL4000 series
19mmm diameter with Titanium casing, fully subermsible, suitable for most wells/bores/weirs |
 |
Ultrasonic sensor Banner T30U and T30Ux series
Used for stream and weir depth gauging - robust and accurate |
 |
Pipe pressure sensor Gems series
Pressure ranges, casing and signal output customisable |
All systems (apart from the limited input monitor) are compatable with all weather sensors listed above.
Operating Charges:
 |
Cellular Operation
Includes 10 minute logging, lifetime base system warranty, data transfer and website costs |
$600 per year |
 |
Satellite Operation
Custom logging intervals, lifetime base system warranty, data transfer and website costs |
$POA |
All prices on this page are in New Zealand dollars and exclude Goods and Services Tax
(GST=12.5%). There is no GST payable on exports. Customers outside New Zealand do not pay
GST and can pay in NZ, AUS or USA dollars. Current exchange rates can be found
here.
Please contact us for more information and
more comprehensive quotes.
|
|
|